Timer For Jet Pulse Filters

Ürünler | TORAMAN OTOMASYON
General Specifications

• Microprocessor Based
• Backlight with 2x16 LCD
• Language option (Turkish - English)
• Industrial IP56 Enclosure Box With transparent glass lid
• Using in 24VDC, 110V - 220V AC Solenoids
• Long-life Transistor or Triac Output
• To determine desired output ranges
• Standard models with 8 - 12 - 16 - 20 - 24 - 28 - 32 Outputs
• Max. 2 solenoids can be connected
• Shock duration can be adjusted (0 - 300 sec)
• Pulse duration adjustable (100 - 1800 ms)
• Freezing time can be monitored (counts down on the screen)
• Working solenoid can be monitored (Number of working solenoid appears on the screen)
• Waiting time can be adjusted after one round is completed (0 - 30 min)
• The system can be put on standby
• Easy programmable menu
• All connections are made with socket connectors.
• Special mode for compartment systems
• Energy-saving DP Algorithm

Technical Specifications

Operating Voltage : 110/220V AC
Operating Frequency : 50/60Hz
Feed Power Consumption : 25W
Max Number of Outlets on a Clipboard : 32
Output voltage, Current max. : (24V – 1A) – (220V – 6A) – (110V – 6A)
DP measuring range : 0 - 70 mbar
Analogue Output Rate : 0 mbar> 4 mA , 70mbar>20mA
DP Hose Diameter : 4mm Pneumatic Hose
Indicator : 2 X 16 LCD
Protection Class : IP 56
Ambient temperature : -10 °C to +120 °C
Connection form : All Connections are Made With Socket Terminals
Mounting method : Mounting on Filter
Dimensions : 310mmx320mmx160mm (WxDxH)

Characteristics of Timer with Dp

• No Need To Use An Extra Transmitter To Measure The Difference Pressure. The Transmitter Is Available On The Card. Displays the Differential Pressure on the Screen and Provides 4 ... 20mA Analog Output. No need for an extra supply for analog output. There is Pressure Difference High Alarm (When the difference pressure read on the screen exceeds the set value, it outputs 24V voltage at the ends of the alarm output. When the value below the set value drops the voltage drops to zero)

Difference Pressure Operation is as the Following;

• Lower and Upper Limits of the Differential Pressure Required are Recorded. The lower and upper limits desired to be at the time of shock are recorded. If the Difference Pressure is at Minimum Value or Less, It Counts Max Freezing Time. If the difference pressure starts to rise, it counts the time of shock by decreasing the time of shock to the inverse proportion. In this way, unnecessary air consumption is prevented.